Carmilla brings into one view the substation node, with wind, grid quality and breaker status, and the production and feed-in meters read over DLMS: you know how much the plant produces, how much it feeds in and why it stopped.

01What it solves

Substation and meters on the same page

Wind measured at the substation

Average speed and minimum, average and maximum direction every quarter hour, with a 16-sector wind rose over the chosen period.

Grid quality and alarms

Phase voltages and currents, frequency, residual current and voltage, box and cabinet temperatures, breaker and grid-protection status over time.

Produced, fed in, availability

Energy and power from the production and feed-in meters, theoretical production from the turbine curve compared with the real one, plant availability and MTBF from the alarm history over time.

02How it works

How it works

  1. 01

    Substation node

    A node in the substation reads anemometer, electrical measurements and breaker digital inputs over Modbus and sends one sample every quarter hour.

  2. 02

    DLMS meters

    The production and feed-in meters, in low and medium voltage, are read over DLMS/COSEM with their transformation constants.

  3. 03

    Aligned series

    Node and meters converge in the same plant: 15-minute, hourly and daily aggregations on the same time base.

  4. 04

    Synoptic and charts

    Synoptic with breaker, grid-fault and extractor status; charts of wind, grid, temperatures, energy and alarms over time.

03Specifications

Under the hood

Substation node
One sample every 15 minutes: wind (speed, min/avg/max direction), phase voltages and currents, frequency, residual, temperatures, 6 digital inputs and 4 outputs
Meters
Production and feed-in over DLMS/COSEM via modem, transformation constants per meter
Data
One file per day and device; 15-min, hourly, daily aggregations; produced, fed-in energy and delta; theoretical production from the turbine curve; availability and MTBF from alarms
Views
Substation synoptic, wind rose, grid statistics, map, alarm status over time, CSV upload and reports

04Regulation and obligations

Connection, metering and incentives of generation plants

  • CEI 0-16

    Technical rule for medium-voltage connection: the interface and general protections (voltage and frequency thresholds) whose trips the substation node records.

  • ARERA, Resolution 458/2016/R/eel — TIME

    Metering of produced and injected energy: the production and feed-in meters read over DLMS with their constants give the metering data with its history.

  • Italian D.Lgs. 199/2021

    Promotion of renewable sources: production measured and available over time as the basis for incentives, guarantees of origin and reporting.

  • GSE obligations for incentivised plants

    Reporting of produced and injected energy: a consistent per-plant history, with meters and substation aligned, simplifies audits.

Indicative references, current at publication date: they do not replace a regulatory check for your case.

05Frequently asked questions

Frequently asked questions on wind monitoring

Do you read turbine or substation data?

Substation and meter data: wind, grid, breakers, produced and fed-in energy. Turbine internals (rotor, pitch) are out of scope.

Where does the theoretical production come from?

From the turbine power curve, set for the plant, applied to the measured wind speed: it serves for comparison with real production, not as a measurement.

Do you compute availability and MTBF?

Yes: from the alarm status over time (breakers, grid faults, extractors) the platform derives downtime hours, plant availability over the period and mean time between failures, comparable with the production lost on the theoretical curve.

Can the meter data be integrated?

Yes: the production and feed-in meters follow the DLMS vertical, with profiles and monthly data through the API.